{"id":831,"date":"2017-10-02T09:50:26","date_gmt":"2017-10-02T07:50:26","guid":{"rendered":"https:\/\/vblog.hochsticher.de\/?p=831"},"modified":"2017-10-02T10:25:05","modified_gmt":"2017-10-02T08:25:05","slug":"how-to-ucs-to-mds-port-channel","status":"publish","type":"post","link":"https:\/\/vblog.hochsticher.de\/?p=831","title":{"rendered":"How to: UCS to MDS Port Channel"},"content":{"rendered":"<p>The last Days I want to create a Port Channel between my UCS Chassis and my MDS Switch. See how to configure and get some hints.<\/p>\n<p><!--more--><\/p>\n<p><em>Remember, during this configuration you loose one FC-Uplink! So check if your Blades see the Paths over both Fabrics!<\/em><\/p>\n<hr>\n<p style=\"text-align: left;\">On my first try I didn&#8217;t get it up. This had to do with the old Firmware of my MDS Switches. So we had to Upgrade to 6.X Release. <a href=\"https:\/\/supportforums.cisco.com\/discussion\/11896686\/create-port-channel-between-ucs-fi-and-mds-9124-f-mode\" target=\"_blank\" rel=\"noopener\">(https:\/\/supportforums.cisco.com\/discussion\/11896686\/create-port-channel-between-ucs-fi-and-mds-9124-f-mode)<\/a><\/p>\n<p>At the second starting point I go with the following Versions:<\/p>\n<ul>\n<li>Cisco UCS 2.2.(7c)<\/li>\n<li>Cisco MDS 6.2(19)<\/li>\n<\/ul>\n<p>Before we create the Channel we have to check:<\/p>\n<ul>\n<li>Cisco MDS\n<ul>\n<li>Feature npiv (enabled)<\/li>\n<li>Feature&nbsp;fport-channel-trunk&nbsp;(enabled)<\/li>\n<li>Put both ports fot the Channel in the same VSAN<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><em>Check Feature:<\/em><\/p>\n<pre class=\"lang:default decode:true\" title=\"Show Feature\">san-1b# show feature\r\nFeature Name          Instance  State\r\n--------------------  --------  --------\r\ndpvm                  1         disabled\r\nevmed                 1         disabled\r\nfabric-binding        1         disabled\r\nfcsp                  1         disabled\r\nfport-channel-trunk   1         enabled\r\nhttp-server           1         enabled\r\nioa                   1         disabled\r\nisapi                 1         disabled\r\nivr                   1         disabled\r\nldap                  1         disabled\r\nnpiv                  1         enabled\r\nnpv                   1         disabled\r\nonep                  1         disabled\r\npoap                  1         disabled\r\nport-security         1         disabled\r\nport_track            1         disabled\r\nprivilege             1         disabled\r\nqos-manager           1         disabled\r\nscheduler             1         disabled\r\nscpServer             1         disabled\r\nsdv                   1         disabled\r\nsfm                   1         disabled\r\nsftpServer            1         disabled\r\nsshServer             1         enabled\r\ntacacs                1         disabled\r\ntelnetServer          1         disabled\r\ntpc                   1         disabled\r\nsan-1b#\r\n<\/pre>\n<p>Enable Feature:<\/p>\n<pre class=\"lang:default decode:true\" title=\"Enable Feature\">san-1b# conf t\r\nEnter configuration commands, one per line.  End with CNTL\/Z.\r\nsan-1b#(config)# feature fport-channel-trunk\r\nAdmin trunk mode has been set to off for\r\n1- Interfaces with admin switchport mode F,FL,FX,SD,ST in admin down state\r\n2- Interfaces with operational switchport mode F,FL,SD,ST.\r\n<\/pre>\n<hr>\n<p>At the next Step we configure the PortChannel in the UCS GUI:<\/p>\n<p>Go to &#8220;SAN&#8221; Tab, &#8220;Create Port Channel&#8221;, Add ID and a Name, Add Ports, Finish.<\/p>\n<!-- default-view.php -->\n<div\n\tclass=\"ngg-galleryoverview default-view  ngg-ajax-pagination-none\"\n\tid=\"ngg-gallery-e92c20fd93a4650857aeb155df19a792-1\">\n\n\t\t<!-- Thumbnails -->\n\t\t\t\t<div id=\"ngg-image-0\" class=\"ngg-gallery-thumbnail-box \" >\n\t\t\t\t        <div class=\"ngg-gallery-thumbnail\">\n            <a href=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/0.jpg\"\n               title=\"\"\n               data-src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/0.jpg\"\n               data-thumbnail=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_0.jpg\"\n               data-image-id=\"84\"\n               data-title=\"0\"\n               data-description=\"\"\n               data-image-slug=\"0\"\n               class=\"ngg-fancybox\" rel=\"e92c20fd93a4650857aeb155df19a792\">\n                <img\n                    title=\"0\"\n                    alt=\"0\"\n                    src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_0.jpg\"\n                    width=\"240\"\n                    height=\"160\"\n                    style=\"max-width:100%;\"\n                \/>\n            <\/a>\n        <\/div>\n\t\t\t\t\t\t\t<\/div> \n\t\t\t\n\t\t\t\t<div id=\"ngg-image-1\" class=\"ngg-gallery-thumbnail-box \" >\n\t\t\t\t        <div class=\"ngg-gallery-thumbnail\">\n            <a href=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/1.JPG\"\n               title=\"\"\n               data-src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/1.JPG\"\n               data-thumbnail=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_1.JPG\"\n               data-image-id=\"85\"\n               data-title=\"1\"\n               data-description=\"\"\n               data-image-slug=\"1-1\"\n               class=\"ngg-fancybox\" rel=\"e92c20fd93a4650857aeb155df19a792\">\n                <img\n                    title=\"1\"\n                    alt=\"1\"\n                    src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_1.JPG\"\n                    width=\"240\"\n                    height=\"160\"\n                    style=\"max-width:100%;\"\n                \/>\n            <\/a>\n        <\/div>\n\t\t\t\t\t\t\t<\/div> \n\t\t\t\n\t\t\t\t<div id=\"ngg-image-2\" class=\"ngg-gallery-thumbnail-box \" >\n\t\t\t\t        <div class=\"ngg-gallery-thumbnail\">\n            <a href=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/2.JPG\"\n               title=\"\"\n               data-src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/2.JPG\"\n               data-thumbnail=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_2.JPG\"\n               data-image-id=\"86\"\n               data-title=\"2\"\n               data-description=\"\"\n               data-image-slug=\"2-2\"\n               class=\"ngg-fancybox\" rel=\"e92c20fd93a4650857aeb155df19a792\">\n                <img\n                    title=\"2\"\n                    alt=\"2\"\n                    src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_2.JPG\"\n                    width=\"240\"\n                    height=\"160\"\n                    style=\"max-width:100%;\"\n                \/>\n            <\/a>\n        <\/div>\n\t\t\t\t\t\t\t<\/div> \n\t\t\t\n\t\t\t\t<div id=\"ngg-image-3\" class=\"ngg-gallery-thumbnail-box \" >\n\t\t\t\t        <div class=\"ngg-gallery-thumbnail\">\n            <a href=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/3.JPG\"\n               title=\"\"\n               data-src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/3.JPG\"\n               data-thumbnail=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_3.JPG\"\n               data-image-id=\"87\"\n               data-title=\"3\"\n               data-description=\"\"\n               data-image-slug=\"3-1\"\n               class=\"ngg-fancybox\" rel=\"e92c20fd93a4650857aeb155df19a792\">\n                <img\n                    title=\"3\"\n                    alt=\"3\"\n                    src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_3.JPG\"\n                    width=\"240\"\n                    height=\"160\"\n                    style=\"max-width:100%;\"\n                \/>\n            <\/a>\n        <\/div>\n\t\t\t\t\t\t\t<\/div> \n\t\t\t\n\t\n\t<br style=\"clear: both\" \/>\n\n\t\n\t\t<!-- Pagination -->\n\t<div class='ngg-clear'><\/div>\t<\/div>\n\n<p>After creating, Disable Port Channel and choose VSAN if you do not use the default VSAN1.<\/p>\n<p><em>I use the UCS Ports 25+27 in VSAN 3370<\/em><\/p>\n<hr>\n<p>So now let&#8217;s configure the MDS Switch:<\/p>\n<p><em>I use the MDS Ports 10+24 in VSAN 3370<\/em><\/p>\n<pre class=\"lang:default decode:true \" title=\"Config PortChannel\">san-1b# conf t\r\nsan-1b(config)# \r\nsan-1b(config)# interface fc1\/10\r\nsan-1b(config-if)# shutdown\r\nsan-1b(config-if)# switchport mode F\r\nsan-1b(config-if)# channel-group 31\r\nfc1\/10 added to port-channel 31 and disabled\r\nplease do the same operation on the switch at the other end of the port-channel,\r\nthen do \"no shutdown\" at both ends to bring it up\r\nsan-1b(config-if)# \r\nsan-1b(config-if)# interface fc1\/24\r\nsan-1b(config-if)# shutdown\r\nsan-1b(config-if)# switchport mode F\r\nsan-1b(config-if)# channel-group 31\r\nfc1\/24 added to port-channel 31 and disabled\r\nplease do the same operation on the switch at the other end of the port-channel,\r\nthen do \"no shutdown\" at both ends to bring it up\r\nsan-1b(config-if)# \r\nsan-1b(config-if)# interface port-channel 31\r\nsan-1b(config-if)# shutdown\r\nsan-1b(config-if)# switchport mode F\r\nsan-1b(config-if)# channel mode active\r\n<\/pre>\n<p>Now enable the Port Channel in UCS GUI and go back to MDS.<\/p>\n<pre class=\"lang:default decode:true  \" title=\"Confg PortChannel-2\">san-1b(config-if)# no shutdown\r\nsan-1b(config-if)# show interface port-channel 31\r\n\r\nport-channel31 is up\r\n    Hardware is Fibre Channel \r\n    Port WWN is 24:1f:00:05:73:b1:3c:68\r\n    Admin port mode is F, trunk mode is on\r\n    snmp link state traps are enabled\r\n    Port mode is F\r\n    Port vsan is 3370\r\n    Speed is 16 Gbps\r\n    admin fec state is down\r\n    oper fec state is down\r\n    5 minutes input rate 224960624 bits\/sec,28120078 bytes\/sec, 16141 frames\/sec\r\n    5 minutes output rate 145118008 bits\/sec,18139751 bytes\/sec, 13232 frames\/sec\r\n      98643 frames input,152616864 bytes\r\n        0 discards,0 errors\r\n        0 invalid CRC\/FCS,0 unknown class \r\n        0 too long,0 too short\r\n      118603 frames output,166967868 bytes\r\n        0 discards,0 errors\r\n      0 input OLS,0  LRR,0 NOS,0 loop inits\r\n      0 output OLS,0 LRR, 0 NOS, 0 loop inits\r\n    Member[1] : fc1\/10\r\n    Member[2] : fc1\/24\r\n    Interface last changed at XXXXXXXXXXXXXX\r\n\r\nsan-1b(config-if)# wr\r\nCopy complete.\r\nsan-1b(config-if)#<\/pre>\n<p>If the Channel does not come up, check if your Ports are up! Maybe you have to do a &#8220;no shutdown&#8221; on the interface.<\/p>\n<pre class=\"lang:default decode:true \" title=\"show-interface\">(config-if)# show interface brief \r\n\r\n-------------------------------------------------------------------------------\r\nInterface  Vsan   Admin  Admin   Status       SFP    Oper  Oper   Port\r\n                  Mode   Trunk                       Mode  Speed  Channel\r\n                         Mode                              (Gbps)\r\n-------------------------------------------------------------------------------\r\nfc1\/1      1000   auto   on      trunking     swl   TE     8      1        \r\nfc1\/2      1000   auto   on      trunking     swl   TE     8      1  \r\n----      \r\nfc1\/10     3370   F      on      up           swl   F      8      31 \r\n----\r\nfc1\/24     3370   F      on      up           swl   F      8      31       \r\n<\/pre>\n<hr>\n<p>Back to GUI. You should see that the Channel is up.<\/p>\n<!-- default-view.php -->\n<div\n\tclass=\"ngg-galleryoverview default-view  ngg-ajax-pagination-none\"\n\tid=\"ngg-gallery-78edca1bdcbd2193e3da977f429923e5-1\">\n\n\t\t<!-- Thumbnails -->\n\t\t\t\t<div id=\"ngg-image-0\" class=\"ngg-gallery-thumbnail-box \" >\n\t\t\t\t        <div class=\"ngg-gallery-thumbnail\">\n            <a href=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/4.JPG\"\n               title=\"\"\n               data-src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/4.JPG\"\n               data-thumbnail=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_4.JPG\"\n               data-image-id=\"88\"\n               data-title=\"4\"\n               data-description=\"\"\n               data-image-slug=\"4-1\"\n               class=\"ngg-fancybox\" rel=\"78edca1bdcbd2193e3da977f429923e5\">\n                <img\n                    title=\"4\"\n                    alt=\"4\"\n                    src=\"https:\/\/vblog.hochsticher.de\/wp-content\/gallery\/ucs-pc\/thumbs\/thumbs_4.JPG\"\n                    width=\"240\"\n                    height=\"160\"\n                    style=\"max-width:100%;\"\n                \/>\n            <\/a>\n        <\/div>\n\t\t\t\t\t\t\t<\/div> \n\t\t\t\n\t\n\t<br style=\"clear: both\" \/>\n\n\t\n\t\t<!-- Pagination -->\n\t<div class='ngg-clear'><\/div>\t<\/div>\n\n<hr>\n<p><em>Enjoy and share&nbsp;\ud83d\ude09&nbsp;!<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The last Days I want to create a Port Channel between my UCS Chassis and my MDS Switch. See how to configure and get some hints.<\/p>\n","protected":false},"author":1,"featured_media":242,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0,"footnotes":""},"categories":[2,3],"tags":[],"class_list":["post-831","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cisco-mds","category-cisco-ucs"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=\/wp\/v2\/posts\/831","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=831"}],"version-history":[{"count":15,"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=\/wp\/v2\/posts\/831\/revisions"}],"predecessor-version":[{"id":858,"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=\/wp\/v2\/posts\/831\/revisions\/858"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=\/wp\/v2\/media\/242"}],"wp:attachment":[{"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=831"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=831"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vblog.hochsticher.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=831"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}